Clack WS2, WS2H & WS2HF Valves: Specs & Manuals | All For Water

Clack Water Specialist · 2"

Clack WS2, WS2QC, WS2H and WS2HF Valves

Official specifications, applications, manuals and replacement parts.

Request a Quote

Clack makes four 2-inch valves in the Water Specialist line. The WS2 and WS2QC are used on commercial softeners and filters. The WS2H and WS2HF are the high-flow versions for industrial, large commercial and municipal systems.

All four have a 2" female NPT or BSPT inlet and outlet. The WS2 mounts on 4"-8UN tanks. The WS2QC, WS2H and WS2HF also accept a 6" flange base or side mounting.

Official manuals

The specifications on this page are taken from these Clack documents. Follow the official manual for installation and programming.

Clack 2" valve specifications

Specification WS2WS2QCWS2HWS2HF
Service flow (15 psi drop) 115 gpm (26.1 m³/h)125 gpm (28.4 m³/h)125 gpm (28.4 m³/h)165 gpm (37.5 m³/h)
Backwash flow (25 psi drop) 80 gpm (18.2 m³/h)85 gpm (19.3 m³/h)125 gpm (28.4 m³/h)175 gpm (39.8 m³/h)
Cv service 29.732.332.342.6
Cv backwash 16.017.025.035.0
Tank connection 4"-8UN4"-8UN, 6" flange or side mount4"-8UN, 6" flange or side mount4"-8UN, 6" flange or side mount
Meter ±5 %, 1.5 – 150 gpm±5 %, 1.5 – 150 gpm±5 %, 1.5 – 125 gpmSold separately
Shipping weight 14 kg (with meter)14 kg (with meter)22.7 kg (with meter)21.8 kg (without meter)
Operating pressure 20 – 125 psi (138 – 862 kPa)
Operating temperature 40 – 110 °F (4 – 43 °C)
Inlet / outlet 2" female NPT or BSPT
Drain line WS2 and WS2QC: 1.5" female NPT · WS2H and WS2HF: 2" female NPT or BSPT
Regenerant refill rate Variable; factory setting 2.2 gpm (8.33 lpm)
Power supply WS2/WS2QC: 12 VAC output · WS2H/WS2HF: 120/230 VAC 50/60 Hz, 24 VDC output

What it is used for

Other Clack models

Frequently asked questions

What is the difference between the Clack WS2 and the WS2H?

According to the official manuals, the WS2 has 115 gpm of service flow and 80 gpm of backwash, while the WS2H reaches 125 gpm in service and 125 gpm in backwash. The WS2H also accepts a 6" flange base or side mounting.

Which Clack 2" valve has the highest flow?

The WS2HF, with 165 gpm (37.5 m³/h) of service flow and 175 gpm (39.8 m³/h) of backwash.

Where can I find the Clack WS2 manual?

The WS2 and WS2QC share a drawings and service manual with the WS1.5; the WS2H and WS2HF share an instruction manual with the WS3. Both PDFs are linked on this page.

Need WS2 / WS2H valves or parts?

We export Clack valves and parts to water treatment dealers across Latin America from Pembroke Park, FL. Tell us the model and quantity and we will confirm wholesale pricing, availability and lead time.

EN English Flag